WWW.SENSORS.VN
  • 0129.Jan.2016
    Friday
    02

    SENSORS VIETNAM- SENSING & CONTROL

    AIR DIFFERENTIAL PRESSURE TRANSMITTER, TEMPERATURE SENSOR, TEMPERATURE AND HUMIDITY SENSOR, PRESSURE SENSOR, CO GAS SENSOR, CO2 GAS SENSOR, SMOKE SENSOR, PROXIMITY SENSOR, CAPACITIVE SENSOR, PRESSURE SWITCH, WARNING LIGHT View
  • 0227.Dec.2025
    Saturday
    03

    TURBIDITY SENSOR RANGE 0-300 NTU

    TURBIDITY SENSOR, WATER TURBIDITY SENSOR, 300 NTU TURBIDITY SENSOR, LIQUID TURBIDITY SENSOR, WASTEWATER TURBIDITY SENSOR, METP-EX 0-300 NTU TURBIDITY SENSOR View
  • 0301.Feb.2016
    Monday
    04

    COMMUNICATION PROTOCOL

    Hardware and software standards that govern data transmission between computers. The term "protocol" is very generic and is used for hundreds of different communications methods. A protocol may define the packet structure of the data transmitted or the control commands that manage the session, or both View
  • 0418.Aug.2025
    Monday
    05

    CARBON MONOXIDE CONTROL PANEL

    CARBON MONOXIDE CONTROL PANEL, CARBON MONOXIDE CONTROL PANELS, CARBON MONOXIDE CONTROLLER, CARBON MONOXIDE WARNING SYSTEM, CARBON MONOXIDE CONTROL PANEL PROSENSE, CARBON MONOXIDE CONTROLLERS View
  • 0512.Jul.2025
    Saturday
    06

    DUCT CARBON DIOXIDE TRANSMITTER EMS KT-241

    DUCT CARBON DIOXIDE TRANSMITTER EMS KT-241 0-5000 PPM,DUCT CARBON DIOXIDE TRANSMITTER EMS KT-241 0-10000 PPM, DUCT CARBON DIOXIDE TRANSMITTER 4-20MA, DUCT CARBON DIOXIDE TRANSMITTER MODBUS RTU, DUCT CARBON DIOXIDE TRANSMITTER EMS 0-10V View
  • 0603.Feb.2016
    Wednesday
    07

    SENSORS VIETNAM- PROVIDE SERVICES MONITORING WIN TURBINE

    The complete condition monitoring solution for wind turbines by Sensors Vietnam – with extensive industry experience: The specialists at Gantner Instruments offer a tried and tested monitoring concept specifically tailored to wind turbines. Our unique solution was originally developed many years ago in close cooperation with wind turbine manufacturers, operators and service departments. View
  • 0731.Jan.2016
    Sunday
    08

    CATELOGY SOLENOID VALVE

    Solenoid valves control the flow of fluids, air, gases and other media in many types of systems and products. Each valve is in turn controlled by an electric current that passes through the solenoid. These electromechanically operated valves come in a broad range of configurations and materials suitable for countless applications. View
  • 0801.Feb.2016
    Monday
    09

    SENSORS VIETNAM -DISTRIBUTION SOLENOID VALVE

    Range of solenoid valve includes types and configurations for a wide variety of hydraulic, pneumatic, instrumentation, medical, refrigeration and aerospace applications. Solenoid valve solutions from US offer reliability, fast and safe switching and compact designs suitable for challenging environments. View
  • 0901.Feb.2016
    Monday
    9

    SENSORS VIETNAM- DISTRIBUTION COLOR SENSORS OF ASTECH- GERMANY

    CROMLAVIEW color sensors are based on the three-range procedure and they process colors according to human perception. Color-sensitive filters, which emulate the tristimulus function of the human eye, facilitate the correct recognition of color values. In terms of color information, opaque solid objects can be evaluated in the epi-illumination method, transparent liquids in the transmitted light method and self-luminous objects… View
  • 1001.Feb.2016
    Monday
    10

    SENSORS VIETNAM- SYNCHRONIZATION GENERATOR SERVICES

    In an alternating current electric power system, synchronization is the process of matching the speed and frequency of a generator or other source to a running network. An AC generator cannot deliver power to an electrical grid unless it is running at the same frequency as the network. If two segments of a grid are disconnected, they cannot exchange AC… View

CUSTOMER SERVICE

www.sensors.vn

Admin@sensors.vn

www.cambien.com.vn

Date 08/Nov/2017 at 12:01 PM - View: 17805



This information touches on some of the most commonly asked aspects of RS-485 communications. B&B Electronics has a free application note available on RS-422/485 that gives a more complete picture of RS-485 networks. Request B&B's RS-422/485 Application Note, available by mail or on our websites, www.bb-elec.com or www.bb-europe.com

What is an RS-485 network? RS-485 allows multiple devices (up to 32) to communicate at half-duplex on a single pair of wires, plus a ground wire (more on that later), at distances up to 1200 meters (4000 feet). Both the length of the network and the number of nodes can easily be extended using a variety of repeater products on the market.

How does the hardware work? Data is transmitted differentially on two wires twisted together, referred to as a "twisted pair." The properties of differential signals provide high noise immunity and long distance capabilities. A 485 network can be configured two ways, "two-wire" or "four-wire." In a "two-wire" network the transmitter and receiver of each device are connected to a twisted pair. "Four-wire" networks have one master port with the transmitter connected to each of the "slave" receivers on one twisted pair. The "slave" transmitters are all connected to the "master" receiver on a second twisted pair. In either configuration, devices are addressable, allowing each node to be communicated to independently. Only one device can drive the line at a time, so drivers must be put into a high-impedance mode (tri-state) when they are not in use. Some RS-485 hardware handles this automatically. In other cases, the 485 device software must use a control line to handle the driver. (If your 485 device is controlled through an RS-232 serial port, this is typically done with the RTS handshake line.) A consequence of tri-stating the drivers is a delay between the end of a transmission and when the driver is tri-stated. This turn-around delay is an important part of a two-wire network because during that time no other transmissions can occur (not the case in a four-wire configuration). An ideal delay is the length of one character at the current baud rate (i.e. 1 ms at 9600 baud). The device manufacturer should be able to supply information on the delay for their products.

Two-wire or four-wire? Two-wire 485 networks have the advantage of lower wiring costs and the ability for nodes to talk amongst themselves. On the downside, two-wire mode is limited to half-duplex and requires attention to turn-around delay. Four-wire networks allow full-duplex operation, but are limited to master-slave situations (i.e. a "master" node requests information from individual "slave" nodes). "Slave" nodes cannot communicate with each other. Remember when ordering your cable, "two-wire" is really two wires + ground, and "four-wire" is really four wires + ground.

How does the software work? 485 software handles addressing, turn-around delay, and possibly the driver tri-state features of 485. Determine before any purchase whether your software handles these features. Remember, too much or too little turn-around delay can cause troubleshooting fits, and delay should be a function of baud rate. If you're writing your own software or using software written for an RS-232 application, be certain that provisions are made for driver tri-state control. Luckily, there are usually hardware alternatives for controlling driver tri-stating. Contact B&B Technical Support for further details.

Connecting a multidrop 485 network. The EIA RS-485 Specification labels the data wires "A" and "B", but many manufacturers label their wires "+" and "-". In our experience, the "-" wire should be connected to the "A" line, and the "+" wire to the "B" line. Reversing the polarity will not damage a 485 device, but it will not communicate. This said, the rest is easy: always connect A to A and B to B.

Signal ground, don't forget it. While a differential signal does not require a signal ground to communicate, the ground wire serves an important purpose. Over a distance of hundreds or thousands of feet there can be very significant differences in the voltage level of "ground." RS-485 networks can typically maintain correct data with a difference of -7 to +12 Volts. If the grounds differ more than that amount, data will be lost and often the port itself will be damaged. The function of the signal ground wire is to tie the signal ground of each of the nodes to one common ground. However, if the differences in signal grounds is too great, further attention is necessary. Optical isolation is the cure for this problem. Contact B&B Technical Support for more details.


Hot news

WHAT IS A THERMOSTAT? WHAT IS A THERMOSTAT, THERMOSTAT FANTINI COSMI, ROOM THERMOSTAT,…
WHAT IS CAPACITIVE SENSORS? Capacitive Sensors M18, Capacitive Sensors M30, Capacitive Sensors NO,…
CATEGORY PHOTOELECTRIC SENSORS A photoelectric sensor, or photo eye, is an equipment…
CATELOGY SOLENOID VALVE Solenoid valves control the flow of fluids, air, gases…
THE PRINCIPLES OF LEVEL… With the wide variety of approaches to level measurement…
SENSORS VIETNAM- SENSING &… AIR DIFFERENTIAL PRESSURE TRANSMITTER, TEMPERATURE SENSOR, TEMPERATURE AND HUMIDITY…
THE PRINCIPLES OF LEVEL With the wide variety of approaches to level measurement…